【Summary】
MNS low-voltage taking out type switch board transfers
the products made of technology according to ABB Company,
suitable for exchanging 50 Hz (60 ) , the working voltage
660V of amount and the following power system. Used for
generating electricity, transmitting electricity, distribution
, electric energy change the control consuming the equipment
with the electric energy.
The switchgear accords with IEC439-1: 1992 and GB7251.
1-1997 <Low-voltage complete set of switch equipment
and controlling equipment, the first part: Test and test
the complete sets with some patterns in pattern >and
ZBK36001<Low-voltage taking out type switchgear >Standard. |
| |
| 【Size of appearance
of the switchgear】 |
 |
| |
【Structure
characteristic】
·
Basic cupboard shelf of switch board for
assemble structure while being sectional, all structure
piece , cupboard of shelf pass zinc-plated to punish,
pass the screw and 8 since. 8 grades and six angle screws
are fastenned, connect each other into a basic frame ,
add corresponding door , seal board , baffle , install
support , bus bar and function Entrance ,etc. spare part
assemble into the intact complete sets according to the
need of scheme change and then. The size of the spare
part in the switch board , the size of the compartment,
implement modulus (modulus unit E =25mm).
· The
taking out type function unit has five kinds of standard
size: 8E/4 , 8E/2 , 8E , 16E , 24E. The total height of
the unit compartment of the function is 72E.
·
Taking out type function unit and cupboard
body have mechanical interlock , make it meet demand of
operating, the state of all only when main return circuit
and auxiliary return circuit disconnection is laid and
moved, the mechanical interlock makes the drawer have
experimental positions, divide and break the position
, join the position and separate the position.
|
| |
【Users
should offer the following materials while ordering】
· A
return circuit scheme and single systematic picture.
· Return circuit principle
picture or wiring diagram two times.
· The permutation picture
of the switch board and level of the electricity distribution
room are fixed up and pursued
· Detail specification
and quantity of the electric equipment in the switch board
· Membrane color that the
surface is painted |
| |
【Technical
parameter】
Working
voltage of amount (V)
|
380、600 |
Insulating voltage of amount
(V)
|
660 |
Specified job electric current(A)
|
Horizontal
bus bar |
630-5000 |
Vertical bus bar |
800-2000 |
Electric current
virtual value of tolerance of a hour of amount
(1s)/Peak value(kA) |
Horizontal bus
bar |
50-100/105-250 |
Vertical bus bar |
60/130-150 |
Grade of outer
cover shelter |
IP30,IP40 |
Size
of appearance high×wide×Deep |
2200×600(800,1000)×600(1000) |
|
| |
|
Address:6
XIYUAN Road
86-0512-88871356
Fax:86-0512-88871360
Zip Code:215011 |
|
|
|
|